站内搜索
|
首页 > Products > Hospital Medical Portable ICU Ventilator with/Without Air Compressor for Adult/Pediatric/Infant
详细信息 Product Name: Hospital Medical Portable ICU Ventilator with/Without Air Compressor for Adult/Pediatric/Infant Model NO.: SLV-1100 Type of Operating Light: Double Operating Light Anesthesia: Semi Open Suction Source: Air LCD Display: With LCD Display Group: Adult Certification: CE, ISO13485 Kind: Gynaecology Type: Ventilator Business Type: Manufacturer H.S Code: 9019200000 Port of Loading: Guangzhou Sample Available: Yes Ventilation Modes: Ippv, A/C, Pcv, Simv, Spont/CPAP, Psv,Sigh,Manu Tidal Volume(Vt): 0-2000ml Frequency (Freq): 1bpm-100 Bpm Oxygen Concentration: 21%-100% I/E: 4:1-1:8 Peep: 0CMH2o-40 CMH2o Pressure Limit: 20 CMH2o-100 CMH2o 1st Wooden Case Packing Size Main Engine: L560*W 560*H 605mm Gw: 35kg Nw: 17kg Air Compressor Packing Size: L670*W700*H 1160 mm Trademark: Shileva Transport Package: Woodcase Specification: 560*560*605mm Origin: China HS Code: 9019200000 Product Description Hospital medical Portable ICU ventilator with/without air compressor for adult/Pediatric/InfantADULT·PEDIATRICFriendly Powerful ReliableApplicationThe ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.Featuresl15" TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.lAir compressor runs stably with low noise, creates quietenvironment for doctorsand patients.lIntegration breathing circuit design.lMultiple working modes such as volume control and pressure limit.lMultiple parameters monitoring interfaceto show clear parameter to the operator, allow operator know the patientconditions in all aspects.lReal time pressure-time, flow-time loop graphics, pressure volume loop graphicsand high precision ETCO2,O2 concentration detection function included.lElectrical PEEP controllBreathing valve isdisassemblyand can be disinfected.SafetylThree levelsalarm system, visual and sound alarm information.lWithmultiple type of alarms, reminding and protection functions.lSelf-check before running, eliminate system mulfuction.lAdvanced power management control technology.lWith built-in backup power supply, whennormalpower supplyshut down, back-up power supplywill startworkautomatically.lSeparatedesign of electric and gas, keep safety running of ventilator.SpecificationsVentilation modes:IPPV,A/C,PCV,SIMV,SPONT/CPAP,PSVVentilator parameter rangesTidal volume(Vt)0 ~2000mLFrequency(Freq)Oxygen concentration1bpm ~ 100 bpm21%-100%I/E4:1~1:8PEEP0cmH2O ~40 cmH2OPressure Limit20 cmH2O ~ 100 cmH2OMonitored ParametersFrequency(Freq)0 /min ~ 100 /minTidal volume(Vt)0 mL ~ 2500 mLMVAirway pressureDynamic lung compliance testingETCO2 Concentration0 L/min ~99L/min0 cmH2O ~ 100 cmH2O1mL/cmH2O ~1000mL/cmH2O0mmHg~152mmHg (0%-20%)Oxygen concentration15 % ~ 100 %Oscillographsdisplay:P-T(pressure - time)F-T(flow - time)P-V loop (pressure - volume loop)V-T(volume - time )ETCO2-T (End-tidal CO2 - time)Alarmsand protectionThe AC power failure alarmPower failure or no connectionInternal battery backup low voltage alarm≤11.3±0.3VNo tidal volumeNo tidal volume within 6sHighMinute VolumealarmLowMinute Volumealarm5L/min-99L/min1L/min-30L/minHigh Airway pressure alarmLowAirway pressure alarmHigh oxygenconcentrationalarmLow oxygenconcentrationalarm20cmH2O-100cmH2O0cmH2O-20cmH2O19%-100%18%-99%Continuous pressure alarm(PEEP+1.5cmH2O) over 16sSuffocation warningFan errorOxygen deficit 5-60sShow on screenShow on screenThe maximum limited pressure<12.5 kPaWorking conditionsGas sourceO2,AIRPressure280kPa-600kPaVoltage~220V±22VPower frequency50Hz± 1HzInput power900VA(with air compressor)250VA(without aircompressor)Ventilation modes:IPPV,A/C,PCV,SIMV,SPONT/CPAP,PSVVentilator parameter rangesTidal volume(Vt)0 ~2000mLFrequence(Freq)Oxygen concentration1bpm ~ 100 bpm21%-100%I/E4:1~1:8PEEP0cmH2O ~40 cmH2OPressure Limit20 cmH2O ~ 100 cmH2OMonitored ParametersFrequence(Freq)0 /min ~ 100 /minTidal volume(Vt)0 mL ~ 2500 mLMVAirway pressureDynamic lung compliance testingETCO2 Concentration0 L/min ~99L/min0 cmH2O ~ 100 cmH2O1mL/cmH2O~1000mL/cmH2O0mmHg~152mmHg (0%-20%)Oxygen concentration15 % ~ 100 %Graphical display:P-T(pressure - time)F-T(flow - time)P-V loop (pressure - volume loop)V-T(volume - time )ETCO2-T (End-tidal CO2 - time)Alarm and protectionThe AC power failure alarmPower failure or no connectionInternal battery backup low voltage alarm≤11.3±0.3VNo tidal volumeNo tidal volume within 6sHighMinute VolumealarmLowMinute Volumealarm5L/min-99L/min1L/min-30L/minHigh Airway pressure alarmLowAirway pressure alarmHigh oxygenconcentrationalarmLow oxygenconcentrationalarm20cmH2O-100cmH2O0cmH2O-20cmH2O19%-100%18%-99%Continuous pressure alarm(PEEP+1.5cmH2O) over 16s
|